• MEDAP S VAC

    Powerful tapping unit
    for the central
    gas supply system

MEDAP S VAC

Excellent combination of best quality and modern design

The different versions of the MEDAP S VAC tapping unit enable silent and extremely powerful aspiration via the terminal unit for vacuum of the central gas supply system. These modern tapping units are extremely lightweight thanks to their impact-resistant ABS plastic housing, and their large, rounded surfaces provide optimum hygienic conditions. A large control valve makes it easy to set the vacuum to the precise level required. Clearly visible ON and OFF buttons on the sides show the unit’s operating status. The MEDAP S VAC is CF-compatible and MR-conditional up to 4.7 teslas.

 
Tapping Unit MEDAP S VAC

Excellent
visual monitoring

The large vacuum gauge with a diameter of 63 mm together with large, clear numbers in kPa and mmHg ensure excellent readability — even from a distance — and a safe workflow.

Indication-specific labelling

Two versions of the MEDAP S VAC are available: one for surgical or bronchial aspiration and one for drainage aspiration. A large, coloured indication label makes it easy to distinguish indications clearly — especially when using multiple tapping units at the same time.

  • MEDAP S VAC B 900 for surgical and bronchial aspiration
  • MEDAP S VAC D 200 for drainage aspiration

MR-conditional

  • Made using special materials
  • MR-conditional up to 4.7 teslas

ON and OFF buttons as a slide switch

The ON and OFF buttons are clearly visible. The markings make it easy to recognise the corresponding setting.



Versions

Tapping units

ATMOS offers the MEDAP S VAC B 900 for surgical and bronchial aspiration as well as the MEDAP S VAC D 200 for drainage aspiration in a variety of connection forms.

S_VAC_Variante_1_160x160Px.jpg

MEDAP S VAC D 200

S_VAC_Variante_2_160x160Px.jpg

MEDAP S VAC B 900

Wall and equipment rail connections

S_VAC_Variante_3_160x160Px.jpg

DIN

S_VAC_Variante_4_160x160Px.jpg

MEDAP

S_VAC_Variante_5_160x160Px.jpg

BS

S_VAC_Variante_6_160x160Px.jpg

NF

S_VAC_Variante_7_160x160Px.jpg

SS

S_VAC_Variante_8_160x160Px.jpg

Equipment rail

Technical Data

MEDAP S VAC B 900MEDAP S VAC D 200
Article numberHM57525620, HM57525619, HM57525621, HM57525622, HM57525623, HM57525624, HM57525625HM57525627, HM57525626, HM57525628, HM57525629, HM57525630, HM57525631, HM57525636
Gas typeVacuumVacuum
Suction capacity100 l/min90 l/min
Max. vacuum–100 kPa
–1000 mbar
–20 kPa
–200 mbar
Vacuum control range0 to –100 kPa0 up to –20 kPa
Connection to CGS / gas pinWall: DIN. MEDAP. BS. NF. SS.
equipment rail. screw fittings
Wall: DIN. MEDAP. BS. NF. SS.
equipment rail. screw fittings
Nominal pressure, gas supply–100 to –60 kPa–100 up to –60 kPa
MR safetyup to 4,7 teslasup to 4.7 teslas
Dimensions (H x W x D)165 x 80 x 125–165 mm165 x 80 x 125-165 mm
Weight360–510 g410–560 g

FAQ

Why does the MEDAP S VAC have a label for specific indications?

Two versions of the MEDAP S VAC are available: one for surgical or bronchial aspiration and one for drainage aspiration. Both versions look the same except for the different vacuum gauge scales. In the intensive care unit, a patient may require both bronchial and drainage aspiration. To avoid confusion, special indication labels show the respective indication.

What function does the hole have on the back of the MEDAP S VAC D 200?
The hole is a safety valve on the patient side that opens at a pressure of 20 kPa and ensures that the maximum vacuum of 20 kPa is not exceeded during drainage.
Why is the DIN gas pin on the MEDAP S VAC so long?
In some intensive care units, the terminal units are in wall channels. An equipment rail often runs just beneath the terminal units. If an overflow protection device is used below the MEDAP S VAC, it could collide with the equipment rail of the wall channel. Therefore, the length of the DIN gas pin was designed in such a way that the MEDAP S VAC cannot come into conflict with the equipment rail even if an overflow protection device is used.
Why can’t the vacuum connection tube to the septic fluid jar be connected directly to the MEDAP S VAC?
In accordance with the international standard ISO 10079 for medical suction equipment, the use of a hydrophobic overflow protection device and a bacterial filter is mandatory. The MEDAP S VAC has the same connection as the MEDAP S AIR. That means the same adapter, and therefore the same hydrophobic bacterial and viral filter, can be connected to the MEDAP S VAC as to the MEDAP S AIR.

Downloads

Title Date Extension Size Language
Brochures & Flyers
Brochure ATMOS Medical Suction Systems 07.09.2023 pdf 3.58 MB en, ru, cn, hu
Brochure ATMOS Suction with Central Gas Supply Systems (CGS) 22.03.2021 pdf 1.96 MB en, fr, ru, cn, es, hu
Brochure MEDAP Medical Suction Systems 22.03.2021 pdf 1.40 MB en, ru, cn, hu
Brochure MEDAP S VAC 22.03.2021 pdf 501.30 KB en, fr, ru, cn, es, hu
Technical Documentation
Declaration of Conformity / Konformitätserklärung Accessories Overflow Protection / Zubehör Überlaufschutz 31.08.2022 pdf 188.62 KB de, en, fr, cn, es, hu
Declaration of Conformity / Konformitätserklärung Suction unit, vacuum / Absauggerät, Vakuum 27.03.2024 pdf 143.98 KB de, en, fr, cn, es, hu
Operating Instructions MEDAP S VAC B 900 / D 200 30.05.2022 pdf 1.28 MB en, cn, es, hu

Accessories

S_VAC_Zubehoer_1_160x160Px.jpg

Mechanical overflow protection

S_VAC_Zubehoer_2_160x160Px.jpg

Hydrophobic bacterial and viral filter

Contact

Are you interested in this product?

The information on this website has been provided solely for use in Germany / ATMOS MedizinTechnik GmbH & Co. KG. This website contains information about products that may not be available in all countries. It is also possible that some products have not or not yet been approved by the competent authorities for certain indications.