MEDAP S AIR
Modern and durable tapping unit
The different versions of the MEDAP S AIR tapping unit enable powerful surgical and bronchial aspiration via a terminal unit for compressed air of the central gas supply system. These modern tapping units are characterised by their high-quality, anodised aluminium construction for a long service life combined with a lightweight design, and they provide optimum hygienic conditions thanks to their large, rounded surfaces. A user-friendly control valve makes it easy to set the vacuum to the precise level required. A clearly visible ON/OFF rotating switch indicates the unit’s operating status.
Versatile
through a width of 52 mm for use in all operating rooms and intensive care units
Powerful
due to a high flow rate suitable for surgical and bronchial aspiration
Maximum safety
through an integrated safety valve at the patient side and a clear vacuum gauge
Applications
- Hospital / clinic
- Outpatient surgery center
High flow rate
The flow rate of 36 l/min, which is high for tapping units for compressed air, noticeably reduces strain on the patient — in the operating room, the intensive care unit, or specialist practice.
ON/OFF switch as a rotating switch
The ON/OFF switch is easy to adjust. The respective position is clearly visible from the front.
MR-compatible
Thanks to their special technology, the modern MEDAP S AIR B 800 tapping units fulfil the requirements for use in MR environments. They are MR-conditional up to 4.7 teslas.
Versions
Wall and equipment rail connections
DIN
MEDAP
BS
NF
SS
Equipment rail
Technical Data
MEDAP S AIR
Gas type
Compressed air
Suction capacity
36 l/min
Max. vacuum
–78 kPa <br>–780 mbar
Vacuum control range
0 up to –78 kPa
Connection to CGS / gas pin
Wall: DIN. MEDAP. BS. NF. SS.<br>rail
Nominal pressure, gas supply
–250 up to –600 kPa
MR safety
up to 4.7 teslas
Dimensions (H x W x D)
140 x 52 x 120–155 mm
Weight
580–720 g
Compressed air consumption
63 l/min at 500 kPa
FAQ
That is the safety valve at the patient side in accordance with the European standard, and it prevents compressed air from flowing toward the patient if the outlet for compressed air becomes blocked.
The compressed air flows downward below the thickened part of the housing. Thanks to this outlet that points downward, the MEDAP S AIR is extremely narrow with a width of 52 mm so that it can even be used when space is limited, for example in an intensive care unit.
The mark indicating that the tapping unit creates vacuum is located in the vacuum gauge ('Vacuum'). On the back of the tapping unit, the mark 'AIR SUPPLY' clearly shows that the tapping unit must be inserted into a terminal unit for compressed air.
In some intensive care units, the terminal units are in wall channels. An equipment rail often runs just beneath the terminal units. If an overflow protection device is used below the MEDAP S AIR, it could collide with the equipment rail of the wall channel. Therefore, the length of the DIN gas pin was designed in such a way that the MEDAP S AIR cannot come into conflict with the equipment rail even if an overflow protection device is used.
In accordance with the international standard ISO 10079 for medical suction equipment, the use of a hydrophobic overflow protection device and a bacterial filter is mandatory. The MEDAP S AIR has the same connection as the MEDAP S VAC. That means the same adapter, and therefore the same hydrophobic bacterial and viral filter, can be connected to the MEDAP S AIR as to the MEDAP S VAC.
Downloads
Title | Date | Extension | Size | Language |
---|---|---|---|---|
Brochures & Flyers | ||||
Brochure ATMOS Medical Suction Systems | 07.09.2023 | 3.58 MB | en, ru, cn, hu | |
Brochure ATMOS Suction with Central Gas Supply Systems (CGS) | 22.03.2021 | 1.96 MB | en, fr, ru, cn, es, hu | |
Brochure MEDAP Medical Suction Systems | 22.03.2021 | 1.40 MB | en, ru, cn, hu | |
Brochure MEDAP S AIR | 22.03.2021 | 409.86 KB | en, fr, ru, cn, es, hu | |
Flyer ATMOS and MEDAP Canister Systems | 26.07.2024 | 1.96 MB | en | |
Technical Documentation | ||||
Declaration of Conformity / Konformitätserklärung Accessories Overflow Protection / Zubehör Überlaufschutz | 27.05.2024 | 183.17 KB | de, en, fr, cn, es, hu | |
Declaration of Conformity / Konformitätserklärung Suction unit, gas powered / Absauggerät, gasbetrieben | 27.03.2024 | 133.12 KB | de, en, fr, cn, es, hu | |
Operating Instructions MEDAP S AIR B 800 | 30.05.2022 | 1.36 MB | en, cn, es, hu |
Accessories
Mechanical overflow protection
Hydrophobic bacterial and viral filter
Contact