• MEDAP S AIR

    Powerful tapping
    unit for aspiration
    with compressed air

MEDAP S AIR

Modern and durable tapping unit

The different versions of the MEDAP S AIR tapping unit enable powerful surgical and bronchial aspiration via a terminal unit for compressed air of the central gas supply system. These modern tapping units are characterised by their high-quality, anodised aluminium construction for a long service life combined with a lightweight design, and they provide optimum hygienic conditions thanks to their large, rounded surfaces. A user-friendly control valve makes it easy to set the vacuum to the precise level required. A clearly visible ON/OFF rotating switch indicates the unit’s operating status.

 
Tapping Unit MEDAP S AIR

Applications

  • Hospital / clinic
  • Outpatient surgery center

High flow rate

The flow rate of 36 l/min, which is high for tapping units for compressed air, noticeably reduces strain on the patient — in the operating room, the intensive care unit, or specialist practice.

ON/OFF switch as a rotating switch

The ON/OFF switch is easy to adjust. The respective position is clearly visible from the front.

MR-compatible

Thanks to their special technology, the modern MEDAP S AIR B 800 tapping units fulfil the requirements for use in MR environments. They are MR-conditional up to 4.7 teslas.



Versions

Wall and equipment rail connections

S_AIR_Variante_1_160x160Px.jpg

DIN

S_AIR_Variante_2_160x160Px.jpg

MEDAP

S_AIR_Variante_3_160x160Px.jpg

BS

S_AIR_Variante_4_160x160Px.jpg

NF

S_AIR_Variante_5_160x160Px.jpg

SS

S_AIR_Variante_6_160x160Px.jpg

Equipment rail

Technical Data

MEDAP S AIR


Art. Nr. HM57525687; HM57525686; HM57525688; HM57525689; HM57525690; HM57525691; HM57525692
Gas type

Compressed air

Suction capacity

36 l/min

Max. vacuum

–78 kPa
–780 mbar

Vacuum control range

0 up to –78 kPa

Connection to CGS / gas pin

Wall: DIN. MEDAP. BS. NF. SS.
rail

Nominal pressure, gas supply

–250 up to –600 kPa

MR safety

up to 4.7 teslas

Dimensions (H x W x D)

140 x 52 x 120–155 mm

Weight

580–720 g

Compressed air consumption

63 l/min at 500 kPa

FAQ

What is the transparent disc covering two holes on the back of the MEDAP S AIR?

That is the safety valve at the patient side in accordance with the European standard, and it prevents compressed air from flowing toward the patient if the outlet for compressed air becomes blocked.

Where does the compressed air flow out of the MEDAP S AIR?

The compressed air flows downward below the thickened part of the housing. Thanks to this outlet that points downward, the MEDAP S AIR is extremely narrow with a width of 52 mm so that it can even be used when space is limited, for example in an intensive care unit.

Where is the marking on the MEDAP S AIR stating that it is a tapping unit for compressed air?

The mark indicating that the tapping unit creates vacuum is located in the vacuum gauge ('Vacuum'). On the back of the tapping unit, the mark 'AIR SUPPLY' clearly shows that the tapping unit must be inserted into a terminal unit for compressed air.

Why is the DIN gas pin on the MEDAP S AIR so long?

In some intensive care units, the terminal units are in wall channels. An equipment rail often runs just beneath the terminal units. If an overflow protection device is used below the MEDAP S AIR, it could collide with the equipment rail of the wall channel. Therefore, the length of the DIN gas pin was designed in such a way that the MEDAP S AIR cannot come into conflict with the equipment rail even if an overflow protection device is used.

Why can’t the vacuum connection tube to the septic fluid jar be connected directly to the MEDAP S AIR?

In accordance with the international standard ISO 10079 for medical suction equipment, the use of a hydrophobic overflow protection device and a bacterial filter is mandatory. The MEDAP S AIR has the same connection as the MEDAP S VAC. That means the same adapter, and therefore the same hydrophobic bacterial and viral filter, can be connected to the MEDAP S AIR as to the MEDAP S VAC.

Downloads

Title Date Extension Size Language
Brochures & Flyers
Brochure ATMOS Medical Suction Systems 07.09.2023 pdf 3.58 MB en, ru, cn, hu
Brochure ATMOS Suction with Central Gas Supply Systems (CGS) 22.03.2021 pdf 1.96 MB en, fr, ru, cn, es, hu
Brochure MEDAP Medical Suction Systems 22.03.2021 pdf 1.40 MB en, ru, cn, hu
Brochure MEDAP S AIR 22.03.2021 pdf 409.86 KB en, fr, ru, cn, es, hu
Technical Documentation
Declaration of Conformity / Konformitätserklärung Accessories Overflow Protection / Zubehör Überlaufschutz 31.08.2022 pdf 188.62 KB de, en, fr, cn, es, hu
Declaration of Conformity / Konformitätserklärung Suction unit, gas powered / Absauggerät, gasbetrieben 27.03.2024 pdf 133.12 KB de, en, fr, cn, es, hu
Operating Instructions MEDAP S AIR B 800 30.05.2022 pdf 1.36 MB en, cn, es, hu

Accessories

S_AIR_Zubehoer_1_160x160Px.jpg

Mechanical overflow protection

S_AIR_Zubehoer_2_160x160Px.jpg

Hydrophobic bacterial and viral filter

Contact

Are you interested in this product?